Fixman 1000V CAT II Digital Multimeter
At a Glance: Manual-ranging digital multimeter for AC/DC voltage, DC current, resistance, diode, transistor and battery testing
The Fixman Digital Multimeter is a versatile electrical testing instrument designed for fault finding, maintenance and general electrical diagnostics. Its clearly marked rotary function and range selector provides access to DC voltage measurement up to 1000V, AC voltage measurement up to 750V, DC current measurement up to 10A and resistance measurement up to 2000kΩ. Additional non-contact voltage detection, diode testing, transistor testing and battery-test functions make it a practical companion for technicians, electricians, automotive users and DIY enthusiasts.
From checking batteries and tracing basic electrical faults to measuring voltage, current and resistance, this manual-ranging multimeter combines essential diagnostic functions in one easy-to-use handheld unit.
Product highlights
- AC and DC voltage measurement: Measures DC voltage up to 1000V and AC voltage up to 750V.
- DC current measurement: Provides ranges from 200µA through to 10A for compatible circuits.
- Resistance measurement: Measures resistance across five selectable ranges up to 2000kΩ.
- Non-contact voltage detection: The NCV function helps identify the possible presence of AC voltage without direct conductor contact.
- Diode test: Assists with checking the condition and forward-voltage behaviour of compatible diodes.
- Transistor test: Includes an hFE function for basic compatible transistor testing.
- Battery testing: Dedicated 1.5V and 9V battery-test positions support convenient battery checks.
- Manual range selection: The rotary selector allows the user to choose the required function and measurement range.
- CAT II rated: Marked CAT II for measurements within the applicable category and voltage limits.
Unlimited Blocks, Tabs or Accordions with any HTML content can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules.
Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities.
Features
- Digital display: Presents measurement results in an easy-to-read numerical format.
- Rotary function and range switch: Provides direct selection of voltage, current, resistance and component-test functions.
- Dedicated input terminals: Includes COM, VΩmA and 10A input terminals for the applicable test-lead configuration.
- Protected VΩmA input: The input is marked with fused protection and specified electrical limits.
- Compact handheld design: Convenient for storage in a toolbox and use during maintenance or diagnostic work.
- Multiple diagnostic modes: Combines electrical measurement, NCV detection, diode testing, transistor testing and battery testing.
Benefits
- Versatile fault finding: One instrument covers many common electrical and electronic testing requirements.
- Wide measurement coverage: Multiple selectable ranges accommodate small electronic readings and higher-voltage applications within the instrument's rating.
- Convenient circuit checks: Measure voltage, DC current and resistance without carrying separate instruments.
- Useful component testing: Diode and transistor functions support basic electronic troubleshooting.
- Quick battery checks: Dedicated 1.5V and 9V positions make testing common batteries more convenient.
- Greater measurement control: Manual range selection allows the user to choose a range suited to the expected value.
Application
- General electrical fault finding.
- Automotive and low-voltage electrical diagnostics.
- Battery voltage and condition checks.
- Testing compatible household electrical circuits.
- Electronic component testing.
- Measuring resistance in isolated components and circuits.
- Checking compatible DC current loads.
- Workshop, maintenance and DIY electrical work.
Extra Information
- This is a manual-ranging multimeter; select a range higher than the expected value before taking a measurement.
- Use the COM and VΩmA terminals for voltage, resistance, diode and low-current measurements within the marked input limits.
- Use the dedicated 10A terminal only when measuring current on the 10A range.
- Resistance, diode and transistor testing must only be performed on de-energised circuits or disconnected components.
- The NCV function is an indication aid and should not be treated as definitive proof that a circuit is safe to touch.
- CAT II applies to measurements on suitable circuits directly connected to low-voltage installations, such as appliances and portable equipment, within the meter's marked limits.
- Always inspect the multimeter and test leads before use and follow the operating instructions.
Pro Tips
- If the expected voltage or current is unknown, begin with the highest suitable range and work downward for a clearer reading.
- Check the test-lead positions before every measurement, especially after using the 10A current terminal.
- Measure voltage in parallel with the circuit and current in series with the load.
- For resistance testing, isolate the component and discharge any capacitors before connecting the probes.
- Touch the test probes together before resistance testing to confirm that the leads and meter respond correctly.
- Use the NCV function as an initial screening tool, then verify circuit status using an appropriate contact measurement.
- Turn the rotary selector to OFF when the multimeter is not in use to help preserve the battery.
How to Use
- Inspect the multimeter, test leads, probes and input terminals for damage before use.
- Connect the black test lead to the COM terminal.
- Connect the red test lead to the VΩmA terminal, or to the 10A terminal only when the 10A current range is required.
- Turn the rotary selector to the required measurement function and begin with a range above the expected value.
- Connect the probes correctly to the circuit: in parallel for voltage or resistance and in series for current.
- Read the measured value on the digital display and select a lower range if improved resolution is required.
- Disconnect the probes from the circuit before changing between incompatible functions or moving the red lead between input terminals.
- Turn the selector to OFF after use and store the multimeter and test leads safely.
Specifications
| Description | Spec |
|---|---|
| Brand | Fixman |
| Cat No. | FIX Y1001 |
| Manufacturer Model | Y1001 |
| Product Type | Digital Multimeter |
| Range Selection | Manual |
| Safety Category | CAT II |
| Maximum DC Voltage | 1000V DC |
| DC Voltage Ranges | 200mV, 2000mV, 20V, 200V and 1000V |
| Maximum AC Voltage | 750V AC |
| AC Voltage Ranges | 200V and 750V |
| DC Current Ranges | 200µA, 2000µA, 20mA, 200mA and 10A |
| Resistance Ranges | 200Ω, 2000Ω, 20kΩ, 200kΩ and 2000kΩ |
| Battery Test | 1.5V and 9V |
| Non-Contact Voltage Detection | Yes |
| Diode Test | Yes |
| Transistor Test | hFE |
| Input Terminals | COM, VΩmA and 10A |
| Operating Temperature | 0°C to 40°C, Relative Humidity Below 75% |
| Storage Temperature | -10°C to 50°C, Relative Humidity Below 85% |
In the box:
- 1 x Fixman Y1001 Digital Multimeter
Safety
- Wear appropriate eye protection and electrically rated personal protective equipment for the circuit and working environment.
- Read and understand the operating instructions before using the multimeter.
- Never exceed the voltage, current, measurement-category or terminal limits marked on the instrument.
- Do not use the multimeter if its casing, display, input terminals, probes or test leads are damaged.
- Keep fingers behind the protective guards on the test probes during measurements.
- Never measure voltage while the red lead is connected to the 10A current terminal.
- Disconnect circuit power before measuring resistance or testing diodes and transistors.
- Discharge capacitors and confirm that stored energy has been removed before resistance or component testing.
- Do not change functions, ranges or terminal connections while the probes remain connected to a hazardous live circuit.
- NCV detection is an indication only; verify that a circuit is de-energised using an appropriate contact test before touching conductors.
- Do not use this CAT II meter on circuits or installations requiring a higher measurement category.
- If you are not trained to work safely on electrical systems, have the testing performed by a qualified electrician.