- Stock: In Stock
- Brand: FIXMAN
- Model: FIX Y1009 391569
- Weight: 0.19kg
- Dimensions: 180.00cm x 95.00cm x 40.00cm
- SKU: FIX Y1009
- UPC: 6940425155531
Fixman 600V CAT III Digital Multimeter
At a Glance: 2000-count manual-ranging multimeter with a backlit LCD, data hold and 600V CAT III rating
The Fixman 600V CAT III Digital Multimeter is a compact and capable instrument for electrical testing, fault finding and routine maintenance. It measures AC and DC voltage up to 600V, DC current up to 10A and resistance up to 20MΩ, while also providing continuity and diode-test functions. A clear 2000-count LCD, selectable backlight and data-hold function make readings easier to capture in workshops, electrical panels and poorly illuminated working areas.
The manual-ranging selector gives the user direct control over the measurement function and range. Combined with three clearly identified input terminals, a protective outer housing and a CAT III 600V rating, it is a practical choice for qualified users performing compatible electrical and electronic tests.
Product highlights
- CAT III 600V rating: Designed for compatible measurements within its marked voltage and measurement-category limits.
- 2000-count LCD: Provides a clear digital display for convenient measurement reading.
- AC and DC voltage measurement: Measures both AC and DC voltage up to 600V.
- DC current measurement: Measures compatible DC current from 0.01mA up to 10A.
- Resistance measurement: Covers resistance values from 0.1Ω up to 20MΩ.
- Continuity test: Assists with identifying complete circuits, conductors and electrical connections.
- Diode test: Supports basic checking of compatible diodes and semiconductor junctions.
- Data hold: Freezes the displayed reading for convenient recording or viewing.
- Display backlight: Improves display visibility in dimly lit working areas.
Unlimited Blocks, Tabs or Accordions with any HTML content can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules.
Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities.
Features
- Manual range selection: The rotary selector provides direct control of the required function and measuring range.
- Three input terminals: Includes COM, VΩmA and dedicated 10A connections.
- Protective outer housing: The shaped casing helps improve grip and protect the instrument during normal use.
- Backlight and hold button: Provides quick access to the display-lighting and data-hold functions.
- Battery powered: Operates using two 1.5V AAA batteries.
- Compact handheld format: Convenient for toolbox storage, maintenance calls and workshop diagnostics.
Benefits
- Versatile fault finding: Measures the principal electrical values required for many common diagnostic tasks.
- Improved visibility: The backlit LCD makes readings easier to view in poorly illuminated areas.
- Convenient reading capture: Data hold keeps a measurement on the display after the probes are removed.
- Useful circuit checking: Continuity and diode-test modes support wiring and component diagnostics.
- Controlled measurement selection: Manual ranges allow the user to select a range suited to the expected value.
- Portable operation: AAA battery power allows the multimeter to be used wherever compatible testing is required.
Application
- General electrical fault finding.
- Testing AC and DC voltage.
- Measuring compatible DC current.
- Resistance measurement on isolated circuits and components.
- Checking wires, fuses and electrical connections for continuity.
- Basic diode testing.
- Automotive and low-voltage electrical diagnostics.
- Workshop, maintenance and qualified DIY electrical work.
Extra Information
- This is a manual-ranging multimeter; select a range higher than the expected measurement before testing.
- Use the COM and VΩmA terminals for voltage, resistance, continuity, diode and applicable low-current measurements.
- Use the dedicated 10A terminal only when measuring current with the appropriate 10A range selected.
- Voltage is measured with the multimeter connected in parallel, while current is measured with the meter connected in series.
- Resistance, continuity and diode testing must only be performed on de-energised circuits or disconnected components.
- The CAT III 600V marking applies only when the meter is used correctly with suitably rated test leads and within all marked limits.
- The instrument is specified for indoor operation at altitudes below 2000m.
Pro Tips
- If the expected value is unknown, begin with the highest suitable range and work downward for improved resolution.
- Check the red test-lead position before every measurement, especially after using the 10A input.
- Use the data-hold function when the display cannot be viewed safely while the probes are connected.
- Turn on the backlight only when needed to help extend battery life.
- Touch the probes together before a continuity test to confirm that the test leads and meter respond correctly.
- For resistance and diode testing, isolate the component and discharge all capacitors before connecting the probes.
- Turn the selector to OFF after use and remove the batteries before prolonged storage.
How to Use
- Inspect the multimeter, input terminals, test leads and probe insulation for damage before use.
- Connect the black test lead to the COM input terminal.
- Connect the red test lead to the VΩmA terminal, or to the 10A terminal only when the applicable high-current range is required.
- Turn the rotary selector to the required function and begin with a range above the expected measurement.
- Connect the probes correctly to the circuit: in parallel for voltage and resistance, or in series for current.
- Read the result on the LCD and select a lower range if improved resolution is required.
- Use the hold function when necessary to retain the reading, and the backlight when additional display illumination is needed.
- Disconnect the probes before changing between incompatible functions or moving the red lead between input terminals.
- Turn the selector to OFF after testing and store the instrument and test leads safely.
Specifications
| Description | Spec |
|---|---|
| Brand | Fixman |
| Cat No. | FIX Y1009 |
| Manufacturer Model | Y1009 |
| Product Type | Digital Multimeter |
| Range Selection | Manual |
| Display | LCD |
| Display Count | 2000 Counts |
| Display Backlight | Yes |
| Data Hold | Yes |
| Safety Category | CAT III 600V |
| DC Voltage Range | 0.1mV–600V |
| AC Voltage Range | 0.01V–600V |
| DC Current Range | 0.01mA–10A |
| Resistance Range | 0.1Ω–20MΩ |
| Continuity Test | Yes |
| Diode Test | Yes |
| Input Terminals | COM, VΩmA and 10A |
| Power Supply | 2 x 1.5V AAA Batteries |
| Operating Environment | 0°C to 40°C, Maximum 80% Relative Humidity |
| Operating Location | Indoor Use, Altitude Below 2000m |
| Storage Environment | -10°C to 60°C, Maximum 80% Relative Humidity, Batteries Removed |
In the box:
- 1 x Fixman Y1009 Digital Multimeter
- 1 x Pair of Test Leads
Safety
- Wear appropriate eye protection and electrically rated personal protective equipment for the circuit and working environment.
- Read and understand the operating instructions before using the multimeter.
- Never exceed the 600V rating, measurement category or terminal limits marked on the instrument.
- Do not use the multimeter if its casing, display, input terminals, probes or test leads are damaged.
- Keep fingers behind the protective guards on the test probes during measurements.
- Never measure voltage while the red test lead is connected to the 10A input terminal.
- Disconnect circuit power before measuring resistance, checking continuity or testing diodes.
- Discharge capacitors and confirm that stored electrical energy has been removed before testing.
- Do not change functions, ranges or test-lead terminal positions while connected to a hazardous live circuit.
- Do not use this CAT III meter on circuits requiring a higher measurement category or voltage rating.
- Replace internal protection components only with components of the specified type and rating.
- If you are not trained to work safely on electrical systems, have the testing performed by a qualified electrician.